港汇 Welcome to the official website of GangHui!

Dongguan Ganghul Refrigeration
Electromechanical Equipment CO., Ltd.

Professional sales ofvarious brands of air-conditioning compressors, refrigeration
compressors and various brands of chillers, dryers and refrigeration accessories

Image name

Miss Deng:18922776417
Mr. Huang:13450460020
Mr. Zhang:13922978523

Service Hotline:

Miss Deng:18922776417

Mr. Huang:13450460020

Mr. Zhang:13922978523

Email:

1536214764@qq.com

673047694@qq.com

Company address:

No. 15, North Second Alley, Lianhe Road, Fulong Village, Shipai Town, Dongguan City

Image name

Follow GangHui

Follow Hong Kong Dollar WeChat
Official Account

 

+
  • 顺驰工机三滤配件图淘宝图4.png
  • 油滤2.png
  • 油分芯1.png
  • 空滤1.png

Permanent Magnet Variable Frequency Silent Air Pump, Industrial-Grade Screw Air Compressor—Three Filters and One Oil

1. Air Filter Replacement Method Use a flathead screwdriver to loosen the locking ring screw, then gently lift out the air filter element and blow out any dust inside or replace it altogether. (Replace every 2,500 operating hours; blow off dust every 500 hours.) Oil Filter Replacement Method Use a belt wrench to hold the oil separator and turn it counterclockwise to remove and replace it. (Replacement interval: every 3,000 operating hours.) Note: When replacing the oil filter and oil separator, make sure to perform the replacement after the machine has been shut down and depressurized. Oil Separator Replacement Method Use a belt wrench to hold the oil separator and turn it counterclockwise to remove and replace it. (Replacement interval: every 3,000 operating hours.) Note: When replacing the oil filter and oil separator, make sure to perform the replacement after the machine has been shut down and depressurized. Lubricating Oil Replacement Method Unscrew the hexagonal bolt at the end of the ball valve, rotate the green handle to drain the oil. After draining, return the handle to its original position. Unscrew the bolt and inject lubricating oil through this opening until the oil level reaches the upper mark on the oil-level sight glass. Lubricating oil replacement interval: The first replacement should be done after 500 hours of operation; thereafter, replace the oil every 2,500 hours. First Maintenance—After 500 Hours—Replace the Oil Filter Element and Screw Compressor Oil Immediate Maintenance Upon High-Temperature Alarm—If the machine is not maintained for an extended period, the oil quality will deteriorate significantly, failing to provide adequate cooling and causing the machine to shut down due to overheating. Second Maintenance—Between 2,000 and 3,000 Hours—The second maintenance requires replacing the oil filter element, air filter element, oil separator element, and screw compressor oil. Friendly Reminder: The maintenance consumables for machines of the same model but from different years and batches may vary slightly. To ensure accuracy and avoid any mistakes, customers who wish to purchase consumables are kindly requested to provide both the machine’s nameplate and an internal photo of the machine, so we can accurately match the appropriate consumables for you.

Keywords:

Product Description

1. Air filter replacement method

Use a flathead screwdriver to loosen the locking ring screw, then gently remove the air filter element and blow out any dust inside or replace it. ( Each use 2500 Needs to be replaced hourly, each 500 Dust needs to be blown off hourly. )

 

  1. Oil Filter Replacement Method

Use a belt wrench to hold the oil separator and turn it counterclockwise to unscrew and replace it. ( Replacement time : After use 3000 Hour ) Precautions : The oil filter and oil separator should be replaced after the machine has been shut down and depressurized.

 

  1. Oil Change Method

Use a belt wrench to hold the oil separator and turn it counterclockwise to unscrew and replace it. ( Replacement time : After use 3000 Hour ) Precautions : The oil filter and oil separator should be replaced after the machine has been shut down and depressurized.

 

  1. Lubricant Replacement Method

Unscrew the external hexagonal screw at the end of the ball valve, rotate the green handle to drain the oil. After draining, return the screw to its original position. Unscrew the bolt and inject lubricating oil through this opening into the oil-level sight glass, ensuring that the oil level reaches the uppermost mark on the oil-level indicator. Lubricant replacement schedule: : The first replacement time is: 500 Hours, and then every 2500 Change it once an hour.

 

  1. First maintenance 500 Hour --- Replace the oil filter and screw compressor oil.

 

  1. Immediately schedule maintenance upon receiving a high-temperature alarm. --- Long-term lack of maintenance , The oil quality is too poor to provide adequate cooling, causing the machine to shut down due to overheating.

 

  1. 2000-3000 Second-level maintenance per hour --- The second maintenance requires replacing the oil filter element. , Air filter element, oil separator element, and screw compressor oil

 

Friendly Reminder : Maintenance consumables for machines of the same model but from different years and batches may vary slightly. To ensure absolute accuracy, customers planning to purchase consumables are kindly requested to provide both the machine’s nameplate and an image of the machine’s interior, so we can accurately match you with the right consumables.


Online Message

If you have any good suggestions or comments about our company, or if you’d like to learn more about our products, please fill out the form below. We’ll get in touch with you as soon as possible!

Hong Kong dollar

Miss Deng:18922776417
Mr. Huang:13450460020
Mr. Zhang:13922978523

img

Email:1536214764@qq.com/ 673047694@qq.com
Company Address: No. 15, Alley 2, North of Lianhe Road, Fulong Village, Shipai Town, Dongguan City

Copyright © 2021 Dongguan Ganghui Refrigeration & Mechanical Equipment Co., Ltd.

Power by:www.300.cn | SEO | Privacy Policy 

Business license