Screw Air Compressor, Permanent Magnet Variable Frequency, 7.5 kW, 11/15/22/37, Industrial-Grade Oil-Free Silent Air Compressor, Includes Three Filters and One Oil Consumable.
Category:
Keywords:
Product Description






1. Air filter replacement method
Use a flathead screwdriver to loosen the locking ring screw, then gently remove the air filter element and blow out any dust inside or replace it. ( Each use 2500 Needs to be replaced hourly, each 500 Dust needs to be blown off hourly. )
- Oil Filter Replacement Method
Use a belt wrench to hold the oil separator and turn it counterclockwise to unscrew and replace it. ( Replacement time : After use 3000 Hour ) Precautions : The oil filter and oil separator should be replaced after the machine has been shut down and depressurized.
- Oil Change Method
Use a belt wrench to hold the oil separator and turn it counterclockwise to unscrew and replace it. ( Replacement time : After use 3000 Hour ) Precautions : The oil filter and oil separator should be replaced after the machine has been shut down and depressurized.
- Lubricant Replacement Method
Unscrew the external hexagonal screw at the end of the ball valve, rotate the green handle to drain the oil. After draining, return the screw to its original position. Unscrew the bolt and inject lubricating oil through this opening into the oil-level sight glass, ensuring that the oil level reaches the uppermost mark on the oil-level indicator. Lubricant replacement interval: : The first replacement time is: 500 Hours, and then every 2500 Change it once an hour.
- First maintenance 500 Hour --- Replace the oil filter and screw compressor oil.
- Immediately schedule maintenance upon receiving a high-temperature alarm. --- Long-term lack of maintenance , The oil quality is too poor to provide adequate cooling, causing the machine to shut down due to overheating.
- 2000-3000 Second-level maintenance per hour --- The second maintenance requires replacing the oil filter element. , Air filter element, oil separator element, and screw compressor oil
Friendly Reminder : Maintenance consumables for machines of the same model but from different years and batches may vary slightly. To ensure there are no mistakes, customers who wish to purchase consumables are kindly requested to provide both the machine’s nameplate and an image of the machine’s interior, so we can accurately match you with the right consumables.
Online Message
If you have any good suggestions or comments about our company, or if you’d like to learn more about our products, please fill out the form below. We’ll get in touch with you as soon as possible!
Miss Deng:18922776417
Mr. Huang:13450460020
Mr. Zhang:13922978523
Email:1536214764@qq.com/ 673047694@qq.com
Company Address: No. 15, Alley 2, North of Lianhe Road, Fulong Village, Shipai Town, Dongguan City
Copyright © 2021 Dongguan Ganghui Refrigeration & Mechanical Equipment Co., Ltd.
Power by:www.300.cn | SEO | Privacy Policy
Welcome to the official website of GangHui!