Instruction Manual for the Small Superman Temperature-Controlled SM102-2 Electronic Microcomputer Temperature Controller

22-08-31

Instruction Manual for the Small Superman Temperature-Controlled SM102-2 Electronic Microcomputer Temperature Controller

Instruction Manual for the Xiao Chao Ren SM102-2 Microcomputer Temperature Controller

★ You must hold down the “Select” key for 5 seconds to set (or modify) parameters between “F1” and “F7” as well as between “H1” and “H2”.
★ Temperature Difference: Example: Lower Limit Temperature -15℃ + Temperature Difference +5℃ “F2”; -15℃ = -10℃ (Lower Limit -15℃, Upper Limit -10℃)
After setting the parameters between “F1” and “F7” and “H1” and “H2,” you must press the “Select” key to return to the temperature-display mode or allow the system to automatically reset (within 12 seconds).

Delay termination: ★ When first powered on, you must hold down the “Add” button for 5 seconds to quickly enter the cooling mode.

Defrosting Instructions: ★ Manual Defrost: You must press the “Manual Defrost” button to activate the defrost function. The defrost cycle will end according to the originally set defrost time and defrost temperature.
Afterward, the controller will operate automatically in a cyclic manner, following the originally set defrost interval, duration, and temperature.
★ Defrost Off: The defrost interval is set to 00“F3,” indicating that the automatic defrost function is disabled. If defrosting is required, you must hold down the “Manual Defrost” button.
It takes 5 seconds to start defrosting, but the defrost cycle must be ended according to the originally set defrost time and defrost temperature.
★ Stop defrosting: Press and hold the “Minus” button for 5 seconds to quickly stop defrosting.

Delay instructions: ★ After power-on, delay 2-3 minutes before starting the compressor, then delay another 30 seconds before starting the fan.

Fault Display: ★ The controller displays “FFF”. First, check whether the sensor is properly connected or damaged; then replace the refrigeration lead wire and probe.
★If the controller displays “HHH,” first check whether the sensor is properly connected or damaged, then replace the defrost lead and probe.

Menu Name Setting Operations and Technical Specifications Factory Settings
F1 Low-Temperature Setting (Lower Limit) ★Press and hold the “Select” button for 5 seconds; the first two digits will display “F1” -15℃
★ Temperature setting range: ±50℃; temperature control range: ±50℃. (Arbitrarily settable)
F2 Set Temperature Difference ★ Press the “Select” key; the first two digits will display “F2” (any setting from 1 to 20℃) 5℃
F3 Defrost Interval ★Press the “Select” key; the first two digits will display “F3”, (any setting from 0 to 250 hours) 6 hours
F4 Defrost Time ★Press the “Select” key; the first two digits will display “F4”. (Set any value between 10 and 60 minutes) 30 minutes
F5 Defrost Stop Temperature ★ Press the “Select” key; the first two digits will display “F5” (set any value between 5-25℃) 15℃
F6 Delayed Water Drip After Defrosting ★ Press the “Select” button; the first two digits will display “F6”, (set arbitrarily between 4 and 15 minutes) 5 minutes
F7 Cooling Temperature Correction ★ Press the “Select” key; the first two digits will display “F7”. (1±5℃ is used to correct temperature measurement errors.) 00
H1 Compressor Operation ★Press the “Select” key; the first two digits will display “H1” (set any duration between 10 and 100 minutes) 15 minutes
H2 Compressor Shutdown ★ Press the “Select” key; the first two digits display “H2” (set any duration between 20 and 180 minutes) 30 minutes

Note: After the refrigeration sensor fails, the automatic on/off cycling function in “H1 and H2” will be automatically activated.
The temperature parameters for the “H1” and “H2” functions should be set according to the user’s desired temperature. (For accurate temperature sensing, it’s best to place a mercury thermometer nearby.)

Opening dimensions: 113mm wide × 45mm high

Hong Kong dollar

Miss Deng:18922776417
Mr. Huang:13450460020
Mr. Zhang:13922978523

img

Email:1536214764@qq.com/ 673047694@qq.com
Company Address: No. 15, Alley 2, North of Lianhe Road, Fulong Village, Shipai Town, Dongguan City

Copyright © 2021 Dongguan Ganghui Refrigeration & Mechanical Equipment Co., Ltd.

Power by:www.300.cn | SEO | Privacy Policy 

Business license