What exactly are the reasons behind a refrigeration compressor failing to return oil?

22-08-31

What exactly are the reasons behind a refrigeration compressor failing to return oil?

1. Insufficient Lubrication: While a lack of oil will certainly lead to insufficient lubrication, insufficient lubrication does not necessarily mean there’s a shortage of oil. The following three factors can also cause inadequate lubrication: - The lubricant fails to reach the bearing surface. - Although the lubricant does reach the bearing surface, its viscosity is too low to form an oil film of sufficient thickness. - The lubricant reaches the bearing surface but decomposes due to overheating, thereby losing its lubricating effectiveness.

 

2. Oil Depletion: Oil depletion is one of the most easily identifiable compressor faults. When a compressor is low on oil, there will be very little or even no lubricating oil left in the crankcase. If the lubricating oil discharged from the compressor fails to return, the compressor will suffer from oil depletion. There are two primary methods for oil return to the compressor: oil separator return and suction line return.

 

3. The root cause of oil deficiency does not lie in how much or how quickly the compressor pumps oil; rather, it stems from poor oil return in the system. Installing an oil separator can facilitate rapid oil return and extend the compressor’s run time without oil return. The design of the evaporator and suction line must take oil return into account. Other maintenance measures—such as avoiding frequent starts, scheduling defrosting cycles, promptly replenishing refrigerant, and replacing worn piston components in a timely manner—can also help promote proper oil return. Liquid slugging and refrigerant migration can dilute the lubricating oil, hindering the formation of a stable oil film. Malfunctions of the oil pump and blockages in the oil lines can affect oil supply and pressure, leading to insufficient oil at friction surfaces. High temperatures at friction surfaces can accelerate the decomposition of the lubricating oil, causing it to lose its lubricating properties.

Hong Kong dollar

Miss Deng:18922776417
Mr. Huang:13450460020
Mr. Zhang:13922978523

img

Email:1536214764@qq.com/ 673047694@qq.com
Company Address: No. 15, Alley 2, North of Lianhe Road, Fulong Village, Shipai Town, Dongguan City

Copyright © 2021 Dongguan Ganghui Refrigeration & Mechanical Equipment Co., Ltd.

Power by:www.300.cn | SEO | Privacy Policy 

Business license