Selection and Matching of Thermal Expansion Valves
22-09-08
The purpose of correctly selecting a thermostatic expansion valve: The selection and matching of a thermostatic expansion valve play a crucial role in maximizing the performance of the entire system. A properly chosen thermostatic expansion valve will ensure that the evaporator is utilized to its full potential and consistently matches the thermal load.
When the thermal expansion valve is mismatched with the system, the refrigerant flow rate in the system will fluctuate—sometimes too high, sometimes too low—causing the cooling capacity of the thermal expansion valve to vary accordingly. When the cooling capacity is too low, the evaporator will receive insufficient refrigerant supply, leading to excessive superheat and adversely affecting system performance. On the other hand, when the cooling capacity is excessively high, it can trigger oscillations, causing intermittent over-supply of refrigerant to the evaporator. This, in turn, leads to severe fluctuations in the compressor’s suction pressure and may even result in liquid refrigerant entering the compressor, causing liquid slugging (wet compression).
Selection criteria: Choose based on the type of refrigerant used in the refrigeration system, the range of evaporation temperatures, and the magnitude of the evaporator superheat load.
The selection method and general steps are as follows:
1) Determine the refrigerant model for the system.
2) Determine the evaporator’s evaporation temperature, condensing temperature, and refrigeration capacity.
3) The pressure difference between the inlet and outlet of the thermal expansion valve.
Miss Deng:18922776417
Mr. Huang:13450460020
Mr. Zhang:13922978523
Email:1536214764@qq.com/ 673047694@qq.com
Company Address: No. 15, Alley 2, North of Lianhe Road, Fulong Village, Shipai Town, Dongguan City
Copyright © 2021 Dongguan Ganghui Refrigeration & Mechanical Equipment Co., Ltd.
Power by:www.300.cn | SEO | Privacy Policy
Welcome to the official website of GangHui!