Use of Industrial Valve Bodies for Ammonia

23-01-09

Use of Industrial Valve Bodies for Ammonia

Industrial valves for ammonia: stainless steel ball valves for ammonia, carbon steel ball valves for ammonia, cast steel ball valves for ammonia, and flanged ball valves for ammonia. Actuation methods include manual operation, gear transmission systems, pneumatic actuation, and electric actuation. In physicochemical experiments, gases such as O2, N2, radon, and argon are often required. These gases are typically stored in high-pressure gas cylinders. During use, a pressure regulator is employed to reduce the gas pressure to the range needed in the laboratory, and further fine adjustments are made using additional control valves before the gas is introduced into the application system. The ball valves commonly used for ammonia are referred to as industrial valves for ammonia.

1. Regarding the common defects of general gate valves—poor corrosion resistance and easy cracking of the valve body—based on the actual characteristics of the medium, ammonia-service industrial valves employ corrosion-resistant steel (carbon steel supplemented with corrosion-resistant alloy elements) for the valve body material. This material is resistant to corrosion by ammonia gas and liquid chlorine, and can withstand extremely low temperatures down to -40°C, thereby fully meeting the operational requirements under various working conditions.

2. The sealing pair of the liquid chlorine shut-off valve adopts a ball-and-flat configuration, featuring automatic sealing compensation to provide a double-safety effect. This ensures stable sealing performance, eliminates adhesive wear, and effectively addresses the major challenge of poor sealing performance and frequent leakage when directly using valves in hydraulic pipelines.

3. The sealing structure used in the industrial valve body for ammonia applications incorporates multi-level PTFE-rubber seals to create a combined sealing system, ensuring that the ferrule fittings remain leak-free throughout the gate valve’s service life. This approach effectively addresses the common issue of inadequate sealing in conventional gate valve ferrule fittings, which often result in media leakage and even pose a significant risk of accidents.

 Industrial valve body for ammonia

Appearance and Principle of Industrial Valves for Ammonia:

The high-pressure chamber of the industrial valve for ammonia is connected to the gas cylinder, while the low-pressure chamber serves as the gas outlet and is connected to the application system. The high-pressure gauge indicates the pressure of the gas stored in the cylinder. In the low-pressure gauge, the outlet pressure can be adjusted by turning the adjusting nut. During operation, first open the main valve of the gas cylinder, then rotate the pressure-adjusting nut on the low-pressure gauge clockwise, which compresses the main torsion spring and activates the diaphragm, spring washer, and small chain, thereby opening the float plate. As a result, the high-pressure gas entering from the inlet passes through a throttling device to reduce its pressure before flowing into the low-pressure chamber and exiting via the outlet to the working system. By rotating the adjusting nut, you can change the relative height at which the float plate starts to move, thus regulating the flow rate of the high-pressure gas and achieving the desired pressure level. All industrial valves for ammonia are equipped with safety valves. These safety valves ensure the safe operation of the ammonia pressure regulator and also serve as anomaly detection devices for ammonia ball valves.

How to use Q41F16C:

1. Depending on the different application standards, ammonia pressure regulators come in many specifications and models. For imported systems, the minimum inlet pressure is typically no less than 2.5 times the outlet pressure. There are numerous specifications for the outlet pressure; generally, the maximum outlet pressure is as follows:

2. When assembling industrial valves for ammonia applications, make sure that the connection specifications and model numbers match those of the corresponding connecting fittings. Ammonia ball valves use a hemispherical joint, which achieves a perfect fit by tightening the nut. Therefore, during operation, it is essential to keep both hemispherical surfaces smooth to ensure optimal sealing performance.

3. Industrial valve bodies used for ammonia must be kept away from vegetable oils to prevent fire hazards and safety incidents.

4. When stopping operation, first release any residual gas from the pressure regulator, and then loosen the adjusting nut to prevent the vibration isolator from undergoing long-term deformation due to sustained stress.

5. Industrial valve bodies for ammonia applications should, as much as possible, be protected from collisions and vibrations and must not come into contact with corrosive gases.


Hong Kong dollar

Miss Deng:18922776417
Mr. Huang:13450460020
Mr. Zhang:13922978523

img

Email:1536214764@qq.com/ 673047694@qq.com
Company Address: No. 15, Alley 2, North of Lianhe Road, Fulong Village, Shipai Town, Dongguan City

Copyright © 2021 Dongguan Ganghui Refrigeration & Mechanical Equipment Co., Ltd.

Power by:www.300.cn | SEO | Privacy Policy 

Business license