Ammonia Industrial Valve Manufacturer: Tips for Using Bread Maker Chiller Units—Save This Now!

23-01-19

Ammonia Industrial Valve Manufacturer: Tips for Using Bread Maker Chiller Units—Save This Now!

  Manufacturer of industrial valves for ammonia applications: The sequence for turning the bread-making chiller unit on and off should ensure normal operation after the air-conditioning host is started. What must be guaranteed? Let’s analyze this together below.

 Industrial valve body for ammonia

  1. Manufacturer of industrial valves for ammonia applications: The condenser of the bread machine chiller has excellent heat dissipation. Otherwise, the condensing temperature and corresponding condensing pressure of the bread machine chiller will become excessively high, triggering the chiller’s high-pressure protection device to activate and shut down the unit, and potentially even causing a malfunction.

  2. Manufacturer of industrial valves for ammonia applications: In a bread machine chiller unit, the chilled water inside the evaporator must circulate continuously. Otherwise, if the chilled water temperature drops too low, the chilled-water temperature protection device will activate and shut down the system. Alternatively, the chiller’s low-pressure protection device may trip due to excessively low evaporating temperature and corresponding evaporating pressure, causing the unit to stop altogether. In extreme cases, the chilled water in the evaporator could freeze, damaging the equipment. Therefore, the startup sequence for the chiller unit is as follows (must be strictly followed): Cooling tower fan on → Cooling water pump on → Chilled water pump on → Chiller unit on. The shutdown sequence for the chiller unit is as follows (must be strictly followed): Chiller unit off → Cooling tower fan off → Cooling water pump off → Chilled water pump off.

  Ammonia Industrial Valve Manufacturer: What are the things to keep in mind when using a bread machine chiller? Let’s analyze this together below.

  1. When shutting down, turn off the chiller half an hour before starting work and turn off the chilled water pump after work ends. This helps conserve energy, prevent downtime, and protect the unit. 2. Before starting the refrigeration cycle, make sure all valves on the heating circuit pipelines are closed.

  Ammonia Industrial Valve Manufacturer: What is the operating procedure for bread-making chiller units? Let’s analyze it together below.

  1. Preparations before startup: 1) Confirm that the power supply to the unit and the controller has been connected. 2) Confirm that the cooling tower fan, cooling water pump, and chilled water pump have been turned on. 3) Confirm that the fan coil units at the terminal end are energized.

  2. Start-up. 1) Press the status key on the keyboard, then switch the ON/OFF toggle switch on the lower unit of the keyboard to the ON position. 2) The unit will perform a self-check. After a few seconds, one compressor will start up, and the other compressor will start up once the load increases. 3) Once the unit is started, all operations become fully automatic; the unit will automatically turn on and off in response to changes in the cooling load (the supply and return water temperatures of the chilled water).

  3. Normal Operation. 1) During normal operation of the unit, the controller will monitor system parameters such as oil pressure and motor current. If any issues arise, the control system will automatically take appropriate measures to protect the unit and display fault information on the unit’s screen. (For details, please refer to the Installation, Operation, and Maintenance Manual.) 2) During each 24-hour operating cycle, a dedicated person should record the unit’s operational status at fixed time intervals.

  4. Shut down the unit. 1) Simply set the unit’s on/off toggle switch under the keyboard to the OFF position to stop the unit. 2) To prevent damage, do not disconnect the unit’s power supply even after the unit has been stopped.

Ammonia Industrial Valve Manufacturer: How do the fans and pumps of a bread machine chiller operate? Let’s analyze this together below.

1. The cooling tower fan, cooling water pump, and chilled water pump are each controlled independently. Before starting, confirm that the power supply is normal, with no phase reversal or phase defects. 2. Before turning on the water pump, ensure that all valves in the pipeline are fully open.


Hong Kong dollar

Miss Deng:18922776417
Mr. Huang:13450460020
Mr. Zhang:13922978523

img

Email:1536214764@qq.com/ 673047694@qq.com
Company Address: No. 15, Alley 2, North of Lianhe Road, Fulong Village, Shipai Town, Dongguan City

Copyright © 2021 Dongguan Ganghui Refrigeration & Mechanical Equipment Co., Ltd.

Power by:www.300.cn | SEO | Privacy Policy 

Business license